Data sheet 48 f 1m metallized pet close window cs hyde company stocks and converts different types of polyester film dupont mylar type a off white standard industry grade electronics grade type el optically clear and metallic metalized polyester film.
Mylar glass transition data sheet.
Glass transition temperature t g 67 81 c.
How to measure glass transition temperature the most usual test method to determine glass transition temperature of plastics is astm e1356.
Multiplying the indicated change by the sample length gives the thermal dimensional change in the sheet of mylar.
This data sheet also covers the following dupont teijin films which are not branded as mylar products.
When filled with glass particles or fibres.
Vicat softening point astm d1525.
Glass transition temp tg dsc.
Crystallization of bpf epoxy resins is possible in the temperature range between the glass transition point 10 to 20 c 14 to 4 f and the general melting range typically 30 to 60 c 86 to 140 f.
Glass transition temperature c 78 121 375 performance improvement shrinkage 150 c after 30 minutes 1 5 0 4 18 performance improvement typical coefficient of thermal expansion ppm c 22 5 19 0 200 performance improvement 1 3 modulus of elasticity gpa 150 c.
Dupont teijin films types db g2 n5 s1 s2 x2 x2i.
To see matweb s complete data sheet for this material including material property data.
Mylar is 1 7 10 5 in in c 9 5 10 6 in in f.
Ac dielectric strength typical value for mylar 92 el c 25 c 77 f 7 0 kv mil astm d149 and astm d2305 60 hz 500 v sec rate of rise gauge and type at 25 c 77 f minimum values for mylar el film 48el 2 8 kv astm d149 and d2305 75el 3 5 kv minimum average 92el 4 0 kv voltage of 10 sheet 142el 5 5 kv samples 200el 7 7 kv 300el 10 0 kv 60 hz.
Mylar can be aluminized by evaporating a thin film of metal onto it to reduce its permeability.
Color conferring dyes can easily be formulated into pet sheet.
As a guide to estimating changes due to thermal expansion figure 5 gives the dimensional changes in in over a wide temperature range.
This test method covers the assignment of the glass transition temperatures of materials using differential scanning calorimetry or differential thermal analysis.
Type mylar a is a tough general purpose film which is transparent in 12μm through 23μm and translucent in heavier thickness.
Bpf resins modified with heloxy modifiers 7 8 and 61 show a greater tendency to crystallize and should not be stored cold.
This page displays only the text of a material data sheet.